Please use this identifier to cite or link to this item:https://hdl.handle.net/20.500.12259/85441
Type of publication: Straipsnis recenzuojamoje užsienio tarptautinės konferencijos medžiagoje / Article in peer-reviewed foreign international conference proceedings (P1d)
Field of Science: Mechanikos inžinerija / Mechanical Engineering (T009)
Author(s): Kavolėlis, Bronius;Bleizgys, Rolandas;Čėsna, Jonas
Title: Calculation the paremetrs of natural ventilation system of animal shed = Obliczanie parametrow systemu naturalnej wentylacji w pomieszceniach dla zwierząt
Other Title: Obliczanie parametrow systemu naturalnej wentylacji w pomieszceniach dla zwierząt
Is part of: Problemy intensyfikacji produkcji zwierzęcej z uwzględnieniem ochrony srodowiska i standardow UE : 14 międzynarodowa konferencja naukowa, Warszawa 23-24 wrzesnia 2008 r. Warszawa, 2008
Extent: p. 109-112
Date: 2008
ISBN: 9788386264711
Abstract: In design a natural ventilation system for animal shed it is necessary to assess the ventilation induced by thermal buoyancy and wind forces during different seassons and under different animal housing conditions. The ratio of thermal buoyance and wind was established and the methodology was prepared to forecast ventilation intensity based on the calculations of air speed in inlet and outlet openings. The equation was formed to calculate the ratio of size inlet and outlet areas. The accuracy of the methodology was approved by experimental research under natural conditions of barn operation. The difference between the experimental and calculated air speed values in the ouitlet opening was insignificant and was within 0-8% range. According to the analytical and experimental research results it was calculated that in a typical animal house air speed in the outlet of the rooftop was 1.3 m/s (when there is no wind, this speed decreases to 0.3 m/s), ratio ventilation rate of thermal buoyancy and wind forces–0.27; and in order to have all air removed through the rooftop outlet in winter, the area of inlets in the walls does not have exceed 40% of the rooftop outlet area
Internet: https://hdl.handle.net/20.500.12259/85441
Affiliation(s): Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml6.09 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats

Page view(s)

54
checked on May 31, 2020

Download(s)

10
checked on May 31, 2020

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.