Please use this identifier to cite or link to this item:https://hdl.handle.net/20.500.12259/85013
Type of publication: Straipsnis konferencijos medžiagoje Clarivate Analytics Web of Science ar/ir Scopus / Article in Clarivate Analytics Web of Science or Scopus DB conference proceedings (P1a)
Field of Science: Mechanikos inžinerija / Mechanical Engineering (T009)
Author(s): Kavolėlis, Bronius
Title: The parameters of ventilation system in uninsulated cowshed
Is part of: Actual tasks on agricultural engineering : proceeding of the 31. international symposium on agricultural engineering, Opatija, Croatia, 24-28 February 2003, 2003
Extent: p. 301-306
Date: 2003
Note: WOS:000182484900032
Keywords: Thermal buoyancy;wind pressure;Temperatures difference;Ventilation rate
Abstract: In Baltic states the construction of the uninsulated cowsheds increased. The natural ventilation system is mostly installed. The required area of the opening inversely proportional to the speed of the air movement that forms there. There are many methods for calculation the speed of the air movement in the openings and natural ventilation systems parameters. But the results are when calculation according to the warious methodics. The methodics of calculation of the natural ventilation systems parameters, relating the system parameters with the criterion, characterising pollution of the inside air, and evaluating thermal buoyancy and wind pressure, solar irradiance, conditions to avoid condensation the water vapour on the inner surface of external walls and roof has been developed. The suitability of the methodics was testified under experimentally natural exploitation conditions. An experiment has been carried out in a closed uninsulated cowshed with loose housing system for 200 dairy cows the dimensions of 72x21 m. Clean air flows in through the gaps at the top of longitudinal walls and contaminated air is removed through the gap of the ridge. The distance between air inlets and outlets is 3,0 m. The experimentally value of the air speed in outlets was (1,1±102) m/s (p<0.05) and calculation value-1.0 m/s, when wind speed was-2.4 m/s, and difference between indoor and outdoor air temperatures-2,6º C. When selecting parameters of uninsulated cowshed ventilation system, the calculated value of indoor and outdoor temperature difference is 3º C. Recommendation for ventilation rate per dairy cow in summer 610 m³/h, and in winter-550m³/h
Internet: https://hdl.handle.net/20.500.12259/85013
Affiliation(s): Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml5.78 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats

Page view(s)

34
checked on Dec 11, 2019

Download(s)

6
checked on Dec 11, 2019

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.