Please use this identifier to cite or link to this item:https://hdl.handle.net/20.500.12259/81734
Type of publication: Straipsnis kitose duomenų bazėse / Article in other databases (S4)
Field of Science: Mechanikos inžinerija / Mechanical Engineering (T009)
Author(s): Kavolėlis, Bronius;Bleizgys, Rolandas;Čėsna, Jonas
Title: Karvidės optimalus temperatūrinis- drėgmės režimas
Other Title: Optimal Temperature- Humidity Regime of Cowshed
Is part of: Žemės ūkio inžinerija. , Nr. 41(1-2) (2009)
Extent: p. 126-137
Date: 2009
Keywords: Karvidė;Šiluminis rodiklis;Temperatūrų skirtumas;Vėdinimo sistema;Santykinis oro drėgnis;Valdymas;Cowshed;Thermal characteristics;Temperature difference;Relative humidity;Ventilation system;Management
Abstract: Darbo tikslas - pagrįsti skirtingai apšiltintų karvidžių temperatūrinio - drėgmės režimo optimalias reikšmes, taikytinas projektuojant ir eksploatuojant vėdinimo sistemą, bei patikrinti dviejų karvidžių vėdinimo sistemų valdymą, nustatant temperatūrų tarp patalpos ir lauko oro skirtumą, patalpos oro santykinį drėgnį, CO2 koncentraciją. Sudaryta lygtis, siejanti temperatūrų skirtumą su patalpos oro santykiniu drėgniu, lauko klimatinėmis sąlygomis, karvidės šiluminiais rodikliais. Eksperimentiniai tyrimai atlikti dviejose karvidėse, kurios skiriasi apšiltinimo laipsniu: pirmosios karvidės visos išorinės atitvaros neapšiltintos (sienų ir stogo vidutinis šilumos perdavimo koeficientas 4,5 W/(m2K), o antrosios - apšiltintas stogas (jo šilumos perdavimo koeficientas 0,45 W/(m2-K); vėdinimo sistemų valdymu. Apšiltinus stogą, patalpos oro temperatūra šaltuoju laikotarpiu padidėja 4 °C. Abiejų karvidžių suprojektuoti vėdinimo sistemų matmenys tinkami. Tačiau dėl to, kad antrosios karvidės vėdinimo sistemos angos šaltuoju laikotarpiu per daug uždaromos, oro santykinis drėgnis viršija galimą minimalų ir dažnai priartėja prie 100 %
The work objective is to substantiate the optimal values of temperature humidity regime in cowsheds, which is necessary in designing and operating the ventilation systems. In addition, investigate the operation of ventilation systems in two cowsheds by observing the temperature differences between indoor and outdoor air, indoor air relative humidity, CO2 concentration. Having performed analytical research has been drawn an equation, which relates the temperature differences between indoor and outdoor air with the indoor air relative humidity, outdoor climate conditions and thermal factors of cowshed. Experimental researches were carried out in two production cowshed with different thermal factors (one cowshed uninsulated, another with insulated roof - partly insulated) and different operation of ventilation systems. Both cowsheds dimensions of the ventilation system were designed sufficient size. The difference between the predicted and observed temperature humidity regime of uninsulated cowshed was non- essential, and average relative humidity of the indoor air was in line with the minimum possible. But for partly insulated cowshed observed difference between indoor and outdoor temperature humidity was too much, and in winter the indoor air humidity usually exceed the minimum possible and sometime reached 100 %. That's shows that ventilation system management was poor
Internet: https://hdl.handle.net/20.500.12259/81734
Affiliation(s): Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml8.21 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats

Page view(s)

50
checked on Jun 2, 2020

Download(s)

8
checked on Jun 2, 2020

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.