Author(s): Šadzevičius, Raimondas;Gurskis, Vincas;Ramukevičius, Dainius
Title: Parameters of microclimate monitoring results on sheepfold made with straw filler
Is part of: Journal of current construction issues. CEPPIS' 2019. Civil engineering present problems, innovative solutions - circular economy in construction sector / scientific editor J. Gorecki Bydgoszcz : University of science and technology, 2019
Extent: p. 169-177
Date: 2019
Keywords: Microclimate parameters;Renewable local resources;Sheepfold;Straw filler
ISBN: 9788387480073
Abstract: Animals are adversely affected by high relative humidity and low temperatures. The optimum temperature range depends on the species, age and weight of the animals. The aim is to analyze parameters of microclimate (humidity and temperature regime) in sheepfold environment and sheepfold walls made from wooden panels with straw filler and to promote science innovations, the use of effective and renewable local resources (straw) in buildings construction. Humidity, temperature regime parameters of the sheepfold microclimate were monitored by sensors and stored in the data loggers. The article presents analysis of parameters microclimate in sheepfold made from wooden panels with straw filler monitoring results (monitoring period 21/02/2015 – 20/04/2015) of the measurement of the external (outdoor), internal (indoor), inside walls (at the depth 10 and 30 cm) temperatures and relative air humidity. The monitoring results in the sheepfold have shown that the relative humidity of the air is too high. It has been observed that the straw filler performs thermal insulation function – after the outside temperature drops to –6° C, the indoor temperature and temperature inside walls in all the measuring points in the sheepfold did not fall below 0°C
Internet: https://depot.ceon.pl/handle/123456789/17085
Affiliation(s): Hidrotechninės statybos inžinerijos institutas
Vandens ūkio ir žemėtvarkos fakultetas
Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml5.92 kBXMLView/Open

MARC21 XML metadata

Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.